The Philips BrightView XCT is a hybrid Single-Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) system designed for nuclear medicine, featuring a compact footprint and high-resolution, low-dose CT imaging capabilities, combining a 3/4-inch crystal gamma camera with a flat-panel cone-beam CT for attenuation correction and anatomical localization. It features a 205 kg (450 lbs) patient weight limit, 91.4 cm gantry aperture, and 12-second CT rotation. The system is designed for high-resolution imaging with 1 mm isotropic voxels. 


Gantry and Physical Specifications

  • Dimensions: 210 cm (H) x 212 cm (W) x 97 cm (D).
  • Weight (without collimators): 2045 kg (4500 lb).
  • Gantry Aperture: 36" (91.4 cm).
  • Caudal-cephalic tilt: ± 15°.
  • Minimum Room Size: Can fit into a room as small as 15' 6" x 12' (4.72 x 3.66 M), often without requiring special floor reinforcement.
  • Power Requirements: 480 VAC, 50A, three phase.


Patient Table

  • Weight Capacity: 500 lb (227 kg).
  • Dimensions: 243 cm (L) x 47.5 cm (W).
  • Material: Carbon fiber pallet.
  • Height (from floor): 26" to 40" (66.0 cm – 102.8 cm). 


SPECT & CT Performance

  • Detector Geometry: Dual-head variable angle.
  • Detector Material: Sodium Iodide (NaI) crystal, typically 9.5 mm (0.375") thick.
  • CT Technology: Utilizes a flat-panel X-ray detector for cone-beam CT (CBCT).
  • CT Slice Thickness: Achieves high-resolution CT images with slices as thin as 0.33 mm.
  • CT Dose Level: Low-dose CT, with typical attenuation correction dose of < 1 mGy CTDIVOL.
  • Co-planar Imaging: Features a CoPlanar FP design, allowing SPECT and CT acquisitions without table indexing between many scans, which improves registration confidence.
  • Image Reconstruction: Uses Astonish reconstruction technologies (an option) to potentially cut acquisition time in half. 


Operation and Workflow Features

  • Body Contouring: Includes BodyGuard automatic contouring technology to position detectors optimally to the patient's body.
  • Breathing Protocols: Supports flexible protocols that allow patients to breathe normally during both SPECT and CT for attenuation correction, enhancing patient comfort.
  • User Interface: Compatible with the Philips NM Application Suite and Extended Brilliance Workspace for streamlined review and analysis.


Key Specifications

  • Detector: Digital detector with 1 ADC/PMT.
  • CT Resolution: 1 mm isotropic voxels, up to 15 lp/cm, with reconstruction in <1 min.
  • Patient Table: 243 cm L x 47.5 cm W, with 227 kg (500 lbs) capacity.
  • Gantry Dimensions: 210 cm H x 212 cm W x 97 cm D, with ±15° tilt.
  • System Weight: 2045 kg (4500 lb).
  • Power: 480 VAC, 50A, three-phase.
  • Acquisition: 300 or 720 X-ray projections; 12, 24, or 60-second rotation times.
  • Field of View: 47 cm transaxial, 40.6 cm x 53.9 cm rectangular. 


Imaging Features 

  • BodyGuard Technology: Automatic contouring adjusts detectors for optimal image quality.
  • JETStream Workspace: Supports up to 16 energy windows for multi-radionuclide imaging.
  • Low Dose: Provides CT attenuation correction with < 1 mGy
  • Respiratory Protocols: Supports breath-hold (12s) or shallow tidal breathing (24s/60s). 


System Requirements 

  • Minimum Room Size: 13 square meters.
  • Heat Dissipation: ~6831 BTU/hr. 



Specifications